Virtual Tour |
| |
|
| |
Introduction: |
| |
Departmental Testing Station of the Petroleum and Explosives Safety Organisation, has been setup for carrying out necessary statutory tests for administration of Explosives Act, 1884 and Petroleum act,1934 and Rules framed there under. It functions under the overall guidance and control of Chief Controller of Explosives , Nagpur |
| |
|
| |
Statutory Tests: |
| |
Statutory tests for implementation of Explosives Act ,1884 and Petroleum Act 1934 and rules framed there under - |
| |
|
| |
i) Under Rule 6(6), 6(9) and 8(b) of Explosives Rules 1983 for authorization of new explosive compositions, subsequent tests for deciding about deletion or otherwise from list of explosives and testing of packages of explosives respectively |
|
|
|
ii) Under Rule 63 (2) and 4 of Petroleum Rule, 2002 for approval of design of safety fittings of tank lorry and containers/barrels of Petroleum respectively |
|
|
| |
iii) Other statutory test under Gas Cylinder Rules, 1981 and Static and Mobile Pressure Vessel (Unfired) rules, 1981 are to be introduced in future. |
|
|
| |
Quality Control Tests: |
| |
|
| |
Testing service for quality control in the field of products covered under Acts / Rules administered by the Department. |
| |
|
| |
Highlights : |
| |
- UN Classification Tests
- Sound Level Test For Compliance of supreme courts directives
- Modern instrumentation laboratory
- Total computerization of functions proposed
- Standardization of processes, procedures and methodology
- Information and facilitation center
- Library and reference cell
|
| |
|
| |
Modern Instrumentation : |
| |
- Differential Thermal Analyser (DTA)
- Thermo Gravimetric Analyser (TGA)
- Differential Scanning Calorimeter (DSC)
- ICP Optical Emission Spectrometer
- GC Mass Spectrometer
- FTIR
- Microwave Digestor
- UV-VIS Spectro Photometer
- Flame Photometer
- Auto Tirator
- Brookfield Viscometer
- Digital Moisture Determinator
|
| |
|
| |
UN Classification Tests : |
| |
Department of Explosives has developed first time in India , facilities at Departmental Testing Station, Gondkhairy, Nagpur for conducting the UN Classification Tests as per UN Recommendations on the Transport of Dangerous Goods-Manual of Tests and Criteria. |
| |
|
| |
Test Facilities : |
| |
- Thermal Stability Test at 750 C
- 12 Meter High Drop Test
- Single Package Test
- Stack Test
- External Fire (Bonfire) Test
- Friction Impact Test
- Fall Hammer Test
- Small Scale Burning Test
- UN Classifiaction Test
- Deflagration to Detonation Test
|
| |
Substances / Articles to be tested |
| |
- Detonators (All Types)
- Explosives (Slurry/Emulsion/PETN/TNT)
- Cast Boosters
- Pyrotechnics
- Explosives Substances not intended for explosives use like Pharma Grade NG
- Other Dangerous Goods not covered under Explosives Act & Rule
|
| |
CCE Guidelines : |
| |
With a view to streamline the methodology of sample collection, test fee to be charged etc. CCE has issued following guidelines. |
| |
|
| |
Sample Size & Test Fee |
| |
|
| |
|
Acts / Rules |
Statutory Function |
Name of samples |
Sample size |
Test fees |
Accompanying Documents/ Data |
|
Explosives Act , 1884
Explosives Rules , 1983 |
|
Rule 6 ( 6) |
Authorization of new formulation of Explosives |
EXPLOSIVES Gun Powder Slurry/Emulsion/SMS |
500 gms LD 25 kgs SD 20 Nos
|
3,300/- |
Product Specifications *
|
|
Rule 6 (9)
|
To decide about deletion or otherwise of explosives from list of authorized explosives |
Nitro Based |
SD 20 Nos |
5,000/-LD (P) |
|
|
|
|
Booster/ Cast booster |
10 Nos |
7,000/-LD ( C ) |
|
|
|
|
Safety Fuse/ Micro Cord |
30 Mtrs |
9,000/- (S) |
|
|
|
|
Detonating fuse |
100 Mtrs |
9,000/- |
|
|
|
|
- Ordinary Detonators |
50 Nos |
6,500/- |
|
|
|
|
- Electric Detonators |
100 Nos |
5,200/- |
|
|
|
|
- Delay Detonators |
100 Nos |
7 ,000/- |
|
|
|
|
- Nonel |
30 Nos |
10,500/- |
|
|
|
|
-Cord Relay |
30 Nos. |
10,500/- |
|
|
|
|
FIREWORKS |
|
|
|
|
|
|
Shell/Combination/Display items |
5 Nos |
250/- |
|
|
|
|
All fireworks item for full test |
each types |
2 50/- |
|
|
|
|
All fireworks items (only sound producing for sound level test ) |
10 Noseach types |
200/- |
|
|
|
|
PACKAGES |
10 Noseach types |
3375/- |
Two copies of CCE approved drawing for new approval |
|
Rule 8 (b) |
Approval of new /in use package of explosives |
Transport packages of all type of explosives |
7 Nos each types |
3375/- |
Two copies of CCE approved drawing for new approval | |
| |
|
Petroleum Act,1934
Petroleum Rules,2002 |
|
Rule 63 (2)
|
Approval of design of new / in use safety fittings of Tank Lorry |
SAFETY FITTINGS Spark arrestor, Fusible Link, Emergency Vent, Emergency Shut off Valve, Pressure Vacuum Valve |
2 Nos of each fittings |
600/- each for spark arrestor and PV Valve 500/- each for other fittings |
Two copies of CCE approved drawing for new approval |
| |